FUNCTION OF STARTER

Welcome to ELECTRICAL ENCYCLOPEDIA. In this article, we will study about the function of starter in DC Motor.

NEED OF STARTER
Armature Current in DC Motor is given by

Iₐ = (V - E
b)/Rₐ.......eq1

where, V = Supply Voltage

            Eb = Back emf

            Rₐ = Armature Resistance

When the motor is at rest (i.e, speed = 0), then the back emf is also zero (because E
b ∝ Speed). So, the initial armature current at the time of starting is

Iₐ = (V - 0)/Rₐ = V/Rₐ......eq2

Since the armature is designed in such a way that its resistance is low.So as from eq2, the armature will draw a very high inrush current which is 5 to 7 times of the full load current. This high inrush current may heat up the armature and damage the armature winding. Excessive current can also .....READ FULL ABOUT STARTER

Comments

Popular posts from this blog

HOT WIRE INSTRUMENTS

Hello friends and welcome to  ELECTRICAL ENCYCLOPEDIA , in this article we will study about the  Hot Wire Instruments ,  it construction , working , advantages and disadvantages. These type of instruments are mainly used as Ammeter but can be used as Voltmeter by connecting a high resistance in series... read full article

TYPES OF CONTROL SYSTEM

Click  here, if article is not been displayed.

POWER FACTOR IMPROVEMENT

Welcome to  ELECTRICAL ENCYCLOPEDIA.  In this article, we will study about the various methods of  Power Factor Improvement. Power Factor plays a very important role in Electric Power Transmission & Distribution. Low Power Factor has many disadvantages associated to it. Normally, the power factor of the generating station should lie between 0.8-0.9. Sometimes, the power factor is lower and in such cases specials equipments are added to achieve higher power factor.  Some Most Commonly used Equipments are : 1. Static Capacitor 2. Synchronous Condenser 1. STATIC CAPACITOR It is well known that  capacitor draws a leading current , which means that current in the capacitor leads the voltage across the capacitor. This property of the Capacitor is used in Power Factor Improvement. Generally, the Capacitor of the suitable rating is connected in parallel with the equipment having low power factor. This partly or completely neutralises the lagging current dr...